OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor

HK FY-MED TRADING CO., LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor

  • 1
  • 2
  • 3

Weight : Varies

Material : Plastic and Metal

condition : good

MOQ : 1 piece

Price : Negotiable

Packaging Details : standard packaging

Delivery Time : 5-7 day

Payment Terms : T/T etc.

Model Number : OTV-S7

Product Name : Endoscopy Processor

Condition : New/Used

Type : Medical Equipment

Contact Now

OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor

The Olympus OTV-S7 Endoscopic Camera System includes a Visera OTV-S7 Digital Processor, Camera Control Unit (CCU), Coupler, Power Cable, DVI Cable, and choice of standard or autoclavable camera head.

The VISERA Digital Imaging Platform responds to every need in minimally invasive surgery and to your every demand. It is commonly used for urology applications.

Size of OTV-S7 Endoscopy Processor & Camera Head:
  • Dimensions: 382(W)*91(H)*490(D)mm(Maximum)

  • Weight: 9.5kg

HK FY-MED

HK FY-MED, advocating the concept of environmental protection and saving, aims to improve the quality of endoscopic products and the service life of the products, thus helping customers to save costs. In addition, we are committed to developing endoscopic equipment and accessories for a long time so as to meet the needs of our customers. We believe that our long time working in the field of endoscopy will enable us to take our service in the field of endoscopy to the next level.

The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.

OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor

System Overview

The Olympus OTV-S7 is the digital processor and camera control unit (CCU) of the VISERA imaging platform used in minimally invasive surgery. The set typically comprises the OTV-S7 digital processor, the camera control unit, a coupler, power and DVI cables, and a choice of standard or autoclavable camera head. The processor converts the camera head signal into a video image with the colour reproduction, edge enhancement and light metering expected of a dedicated endoscopic chain, and outputs it over DVI to a surgical monitor for the theatre team.

Typical Clinical Use
Urology: cystoscopy, ureteroscopy and resection procedures where a stable, colour-accurate image is required.
General and gynaecological laparoscopy on a VISERA-class camera chain.
Clinics refurbishing an existing Olympus tower who need a matched processor and camera head rather than a mixed-brand stack.
Technical Highlights and Integration
Matched processor and CCU: avoids the white-balance and connector mismatch common in mixed-brand towers.
DVI output for direct connection to modern surgical displays; analogue outputs support legacy monitors and recorders.
Standard or autoclavable camera head options, so the same CCU can serve different sterility workflows.
Chassis 382 (W) x 91 (H) x 490 (D) mm, weight approximately 9.5 kg — a 19-inch rack-friendly footprint for a compact tower.
On-screen enhancement, brightness and white-balance control from the camera head buttons or the front panel.
Installation, Care and Quality Control

Allow free airflow at the rear and sides of the chassis; blocked ventilation is the most common cause of thermal shutdown in theatre towers. Use only the specified lamp and light-guide components with the matching coupler, and confirm earth continuity of the whole stack when it is first installed. Camera heads and couplers should be leak-tested before autoclaving. Each unit we supply is powered on, checked for image output on a test monitor, and inspected for connector and fan condition before packing.

Ordering Notes
What is included in the set?
Processor, CCU, coupler and cables as listed, plus a standard or autoclavable camera head depending on the option you choose. Confirm the exact bundle when requesting a quotation.
New or refurbished?
Both appear in our stock; condition is stated per unit and photographs of the actual item are available.
Delivery?
One piece minimum, dispatch normally within 5-7 working days, freight quoted for your destination.
Product Specification Summary
ParameterValue
Model NumberOTV-S7
WeightVaries
MaterialPlastic and Metal
Product NameEndoscopy Processor
conditiongood
TypeMedical Equipment

Product Tags:

OTV-S7 Endoscopy Processor

      

Endoscopy Camera Head Processor

      

Endoscopy Processor System

      
Quality OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor for sale

OTV-S7 Endoscopy Processor & Camera Head Endoscopy Processor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HK FY-MED TRADING CO., LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)