Product Name : Endoscopy Processor
Condition : New/Used
Type : Medical Equipment
The Olympus OTV-S7 Endoscopic Camera System includes a Visera OTV-S7 Digital Processor, Camera Control Unit (CCU), Coupler, Power Cable, DVI Cable, and choice of standard or autoclavable camera head.
The VISERA Digital Imaging Platform responds to every need in minimally invasive surgery and to your every demand. It is commonly used for urology applications.
Dimensions: 382(W)*91(H)*490(D)mm(Maximum)
Weight: 9.5kg
HK FY-MED, advocating the concept of environmental protection and saving, aims to improve the quality of endoscopic products and the service life of the products, thus helping customers to save costs. In addition, we are committed to developing endoscopic equipment and accessories for a long time so as to meet the needs of our customers. We believe that our long time working in the field of endoscopy will enable us to take our service in the field of endoscopy to the next level.
The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.

The Olympus OTV-S7 is the digital processor and camera control unit (CCU) of the VISERA imaging platform used in minimally invasive surgery. The set typically comprises the OTV-S7 digital processor, the camera control unit, a coupler, power and DVI cables, and a choice of standard or autoclavable camera head. The processor converts the camera head signal into a video image with the colour reproduction, edge enhancement and light metering expected of a dedicated endoscopic chain, and outputs it over DVI to a surgical monitor for the theatre team.
Allow free airflow at the rear and sides of the chassis; blocked ventilation is the most common cause of thermal shutdown in theatre towers. Use only the specified lamp and light-guide components with the matching coupler, and confirm earth continuity of the whole stack when it is first installed. Camera heads and couplers should be leak-tested before autoclaving. Each unit we supply is powered on, checked for image output on a test monitor, and inspected for connector and fan condition before packing.
| Parameter | Value |
|---|---|
| Model Number | OTV-S7 |
| Weight | Varies |
| Material | Plastic and Metal |
| Product Name | Endoscopy Processor |
| condition | good |
| Type | Medical Equipment |
|
|