Model Number : EPX-2500
The EPX-2500 is a user-friendly Xenon processor/light source. The control unit is easy to use and clearly displays all of the functions that are available for the integrated light source. This includes a blood vessel function which enhances the imaging of the vessels. Nine different light settings are available which offer the physician brightly illuminated images.
1. High-Definition endoscopy progressive scan imaging-increased image clarity and resolution
2. Compact, simplified combination platform-reduced footprint with greater ease-of-use
3. 150 watt xenon primary light source-cost-effective, highly-efficient illumination source
4. Automatic white balance-saves time while assuring color accuracy
5. Incremental electronic magnification up to 2X-allows for increased detail when required


The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.
The Fujifilm EPX-2500 is a combined endoscopy video processor and 150 W xenon light source in a single compact platform. Progressive-scan high-definition imaging, automatic white balance and incremental electronic magnification are controlled from one front panel, and the integrated light source offers nine illumination settings plus a blood-vessel enhancement mode that raises the contrast of mucosal vasculature. Combining processor and light source in one chassis reduces tower footprint and cabling, which matters in clinics running several procedure rooms.
Allow clear airflow around the chassis and keep the rear filter clean — a blocked filter is the most common cause of lamp overheating and shutdown. Xenon lamps must be changed only after full cool-down, and the lamp envelope should never be touched with bare fingers. Run the automatic white balance with the scope attached and the light cable connected, and store spare lamps in the procedure room for high-volume days. Each unit is powered on, tested for image output and light intensity, and inspected for connector and fan condition before packing.
| Parameter | Value |
|---|---|
| Model Number | EPX-2500 |
|
|